Setting up V12

  1. Connect your V12 Geophone with your INFRA Datalogger by using any of the available INFRA Sensor Cables.

  2. Start the Datalogger and wait for the initialization process to complete.

  3. Under the menu Nodes you’ll find your V12 unit as three separate sensors:

    GEO V12V- serial number

    GEO V12L- serial number

    GEO V12T- serial number

    where GEO is the Customer string and serial number is the serial number.

  4. For each of the three sensors, set Standard (S01, S02, etc.).

    Then for the chosen standard select

  • Interval time

  • Record time

  • Threshold (level and ON/OFF).

    It is also possible to change the Customer string which in some standards is used to select weighting type.

  1. Activate REG ON, and the measurement will be initiated.