Getting started INFRA V10

A quick guide on how to get your INFRA V10 started

Quick Start V10

  1. Connect your V10 Geophone with your INFRA Datalogger by using any of the available INFRA Sensor Cables.

  2. Start the Datalogger and wait for the initialization process to complete.

  3. Under the menu Nodes you’ll find your V10 unit as GEO V10- serial number, where GEO is the Customer string and serial number is the serial number.

  4. Select GEO V10- in order to set Standard (S01, S02, etc.).

Then, for the chosen standard, select:

  • Interval time

  • Record time

  • Threshold (level and ON/OFF).

Note! When performing a test or reference measurement, make sure that the threshold is set to OFF. Otherwise unnecessary transients will be recorded.

5 Activate REG ON, and the measurement will be initiated.

Note! First registration of interval data is delayed to synchronize to the local time. The delay may last up to one interval period. First presentation of data will then be delayed up to two interval periods. Transient triggering and readout of Live-values are available directly after activation of REG ON.